ATX 400W with Battery Backup function
AUP-520P-S20
                        
            
            
  Production information
                80Plus Bronze Nonstop Power Supply(RS232C signal type)
- Backup function protects PCs at blackout
- 80PLUS BRONZE acquired
- All outputs have the minimum load of 0A
- Less than 1W standby power complying with ErP directive(Contribute to the reducing CO2 emissions and electricity costs)
- Thermo-sensing speed control fan allows for a quiet environment
- 80PLUS BRONZE acquired
- All outputs have the minimum load of 0A
- Less than 1W standby power complying with ErP directive(Contribute to the reducing CO2 emissions and electricity costs)
- Thermo-sensing speed control fan allows for a quiet environment
Output specification

Standard specifications:
| Compatible case size | 
			 PS2 
			 | 
		|
| 
			 Outline drawing 
			 | 
			
			 150Wx86Hx140D 
			 | 
		|
| 
			 Weight 
			 | 
			
			 1.80 kg typ 
			 | 
		|
| 
			 AC 
			 | 
			
			 85 to 264V 
			 | 
		|
| 
			 DC 
			 | 
			
			 24V(Dedicated battery package only) 
			 | 
		|
| 
			 AC 
			 | 
			
			 80% typical at AC 100V/85% typical at AC 200V 
			 | 
		|
| 
			 DC 
			 | 
			
			 80% typ 
			 | 
		|
| 
			 96% min. at AC 100V/90% min. at AC 200V 
			 | 
		||
| 
			 Worldwide 
			 | 
		||
| 
			 AC, DC input 
			 | 
			
			 | 
		|
| 
			 UL60950-1, CSA C22.2 No.60950-1,CCC S&E, CE Marking (LVD, EMC) 
			 | 
		||
| 
			 IEC61000-3-2 (Ed. 2.1) Class D and EN61000-3-2(A14)Class D compliant 
			 | 
		||
| 
			 VCCI-B FCC-B and EN55022-B compliant 
			 | 
		||
| 
			 Low Voltage Directive, EMC Directive 
			 | 
		||
| 
			 Electrostatic discharge: EN61000-4-2 compliant 
			Radiated,radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips/regulations: EN61000-4-11 compliant  | 
		||
| 
			 70,000H min 
			 | 
		||
| 
			 0 to 60 deg C (load derating: 100% at 45 deg C, 70% at 60 deg C) 
			 | 
		||
| 
			 0.5mA max. at AC 100V, 1.0mA max. at AC 200V, 1.2mA max. at AC 240V 
			 | 
		||
| 
			 Forced air cooling 
			 | 
		||
| 
			 | 
		||
| 
			 | 
		||
| 
			 SU-RS (RS232C), SU-BU (buzzer), SU-US2 (USB) 
			 | 
		||
| 
			 Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. 
			 | 
		||
Download file